Nitrogen generators

According to the needs of customers and their requirements, VICI DBS nitrogen generators have different technologies.
Whether you do not have a compressed air connection in the laboratory, require particularly high purity or a high flow rate, with us you will find a model for all circumstances.

Mistral Evolution Nitrogen generators:

The VICI DBS Mistral Evolution is a self-contained generator that produces up to 40 L/min of pure LC/MS grade nitrogen at up to 8 barg (116 psig). Nitrogen is produced by utilizing a combination of compressor and Carbon Molecular Sieve (CMS) technology. High and low-pressure compressors are carefully matched to the CMS demand to ensure quiet and reliable operation. This unique combination of dual compressor technology has several unique advantages over all other nitrogen generators commercially available. 

The 2-stage pressure design allows the compressors to work at their optimum pressure range reducing the stress and results in extending the lifetime of the compressors. This reduces maintenance costs and associated downtime.

Optional an oil-free compressor and dryer is dedicated to produce up to 35 L/min of dry air. With two separate outlets the generator is ideal to support the gas requirements of the Agilent MP AES systems.

                                                                                                             

Whisper O-Series Nitrogen generators:


The VICI DBS Whisper-0 nitrogen generators can produce up to 120 L/min of high purity LC/MS grade nitrogen at pressures up to 8 barg (116 psig). These generators are engineered to transform standard compressed air into a safe regulated nitrogen supply with minimal operator attention and maintenance. Nitrogen is produced by utilizing a combination of filtration and membrane separation technologies.
A standard supply of compressed air is filtered by high efficiency coalescing filters to remove all contaminants down to 0.1 micron. A unique proprietary membrane then separates the air into a concentrated nitrogen stream.
Membrane technology offers many unique performance benefits for LC/MS users including phthalate-free nitrogen, silent operation, no moving parts, and no electrical requirements. The generators can be installed directly in the laboratory with the Whisper-0 mounting to the wall and the Whisper-0 Mini to the floor.
Both require minimal operator attention or maintenance. The generators are designed to run continuously or ondemand providing a clean, dry high purity nitrogen supply.

VICI DBS membrane nitrogen generators require no electricity, have no moving parts and minimal noise.

The Whisper-0 Series is  available as Hybrid. Means Nitrogen + Air can be produced in one system.
These generators are engineered to transform standard compressed air into a safe regulated nitrogen and high purity air supply with minimal operator attention and maintenance. Nitrogen is produced by utilizing a combination of filtration and membrane separation technologies. A standard supply of compressed air is filtered by high efficiency coalescing filters to remove all contaminants down to 0.1 micron. A unique proprietary membrane then separates the air into a concentrated nitrogen stream.
Air is purified using a unique air purification membrane removing contamination and water.

                                                                                                       

HP Plus Tower Nitrogen generators:

The VICI DBS HP Plus Tower produces nitrogen by utilizing a combination of filtration and pressure swing adsorption (PSA) technology. Standard compressed air is filtered by high efficiency coalescing filters to remove all contaminants down to 5 micron.
For ultra-sensitive applications such as GC carrier and make-up gas, units also include the additional heated catalyst module to ensure hydrocarbons are removed to <0.1 ppm. The air then passes through two columns filled with a proprietary blended carbon molecular sieve (CMS) which adsorbs O2, CO2, and moisture. These are desorbed to the atmosphere during the pressure swing cycle leaving a supply of ultra-pure nitrogen.

                                                                                                                         

HP Plus Rack Nitrogen generators:

The VICI DBS HP Plus Rack produces nitrogen by utilizing a combination of filtration and pressure swing adsorption (PSA) technology. Standard compressed air is filtered by high efficiency coalescing filters to remove all contaminants down to 5 micron.

For ultra-sensitive applications, the 19” rack units also include the additional heated catalyst module to ensure hydrocarbons are removed to <0.1 ppm. The air then passes through two columns filled with a carbon molecular sieve (CMS) which removes O2, CO2, and moisture. These are desorbed to the atmosphere during the pressure swing cycle leaving a supply of ultra-pure nitrogen.

Ideal for analyzer applications - stable baseline with increased sensitivity and reputability plus Superior nitrogen purification with long life catalyst.


For more information contact us here.