The sensors are integrated in a so-called "Pod" and are operated by means of the internal battery. The data is transmitted via a mobile network to a "cloud server", where it is processed and then passed on to the user via the Internet. Thus, AQMesh™ offers a modern, cost-effective air measurement system that can be installed almost anywhere without great effort.
Special features
- Up to 2 years battery life (for gas sensors without PM and depending on application)
- Optional with particle sensor for quantity, PM1, PM2,5, PM10
- Optional battery operation
- No power connection and no data line necessary
- AQMesh™ can be attached to lanterns, fence posts, signposts or walls
- Integrated wireless GPRS technology enables data access virtually anytime, anywhere
- Easy installation in just 10 minutes
- Real-time correction of environmental factors and cross-sensitivity effects
Data transfer via "Cloud Server" offers
- Online data access via Internet
- Possibility of setting the data intervals
- Processed measured values
- Diagnostic and service information
- data visualization
- data download
- data security management
- Easy installation of updates
- Software maintenance and repair
components | measuring range |
nitrogen dioxide (NO2) | 0 - 4000 ppb |
nitrogen monoxide (NO) | 0 - 4000 ppb |
ozone (O3) | 0 - 1800 ppb |
moisture | 0 - 100 % relative humidity |
Barometric pressure | 500 - 1500 mbar |
Pod-Temperatur | - 20 bis 100 °C |
Optional: carbon monoxide (CO) | 0 - 6000 ppb |
Optional: sulphur dioxide (SO2) | 0 - 10000 ppb |
Optional: particles (number in P/cm3 and PM1, PM2,5, PM10 in µg/m3) | size range: 0,3 -30 µm |
Technical Specifications | |
weight | Ca. 2 kg |
Dimensions | Ca. 22 x 25 x 17 cm (without antenna) |
power supply | Lithium metal battery(2) for up to 2 years operation (for gas sensors without PM and depending on application) Optional: Battery operation with rechargeable NiMh battery (2 rechargeable batteries and one charger included) |
protection class | IP65 |
communication | GPRS, global multiband operation |
Temperature / Humidity range | - 20 bis + 40 °C / 15 – 85 % RH(3) |